Fix for Sony MZ-R55 Recording Self-start Problem
Hoshing Kwong ([email protected])February 2000
Problem:
Sony MZ-R55 units have been known to go into record mode while at idle and over-write unprotected MD.Cause:
The signal pin attached to the record switch is at a "floating" state and sensitive to battery voltage level.Solution:
Verify that the record switch is functioning properly (not sticky). Solder a small "surface mount type" capacitor (100 nf) between the signal pin of the record switch and ground. Refer to diagram attached for more details.